TD-4100 Oil in Water Monitor

The Turner Designs
TD-4100 reliably detects BTEX, gasoline, diesel, jet fuel and oil in water. The TD-4100 is a nonfouling continuous, on-line monitor that provides hydrocarbon and oil in water monitoring down to low ppb. The TD-4100 is installed for applications that require monitoring of treated and untreated wastewater streams ranging from industrial wastewater, groundwater, process water, produced, potable water intakes, and storm water run-off.

Why Continuous On-Line Monitoring?

Continuous on-line monitoring provides the most responsive feedback loop for measuring hydrocarbons in water. Continuous monitoring is reliable, effective, and recognized for its ability to improve process management for treating, discharging and detecting hydrocarbons in water. Compared to laboratory grab sample analysis, on-line monitoring provides cost effective, continuous, remote, operator unattended measurement of aromatic hydrocarbons in water.

Features of the TD-4100

The Unique Flowcell. The TD-4100 does not have a glass flow cell. Hydrocarbons are detected in a stream of water which falls through an open chamber; the stream does not contact, dirty or foul the optical windows used for oil in water monitoring. A proprietary Air Curtain system keeps optical Windows fog-free in humid environments or hot water applications.

Low Maintenance. There are no tubes, pumps or valves to replace. The system’s one moving part has a life expectancy of greater than 5 years. Routine maintenance involves changing a lamp twice a year and an air filter periodically.

Direct, Continuous Monitoring. The TD-4100 monitors a flowing water stream continuously. No chemicals, no pre-treatment and no manual manipulation of the sample are required to monitor aromatic hydrocarbons.

Accurate. The TD-4100 directly measures aromatic hydrocarbons in water with accuracies that consistently correlate to regulated laboratory methods.

Sensitive. BTEX, gasoline, diesel, jet fuel, crude oil, aromatic solvents and refined petroleum products containing aromatics are detected by the TD-4100 from low ppb (ug/L) to high ppm (mg/L). For example, the TD-4100 can detect 5 ppb of gasoline or diesel fuel in water free of interfering compounds.

Selective. The TD-4100 continuously measures the fluorescence of aromatic hydrocarbon compounds in water. Fluorescence occurs when a molecule absorbs light energy of one specific wavelength and emits light energy of a longer wavelength. Fluorescent compounds each have a unique signature, and these compounds can be displayed as an actual concentration.

Effective Monitoring in Dirty Water. Monitoring fluorescence makes the TD-4100 resistant to interferences by turbid or dirty water which impact on-line UV or IR light scatter instruments. Most substances absorb light, but very few fluoresce; if a substance does not fluoresce at specific wavelengths for the monitored aromatic hydrocarbon, it will not interfere.

Operator Friendly. The TD-4100 is designed for easy operation. Simple on-board software controls alarms, 4-20 mA output, diagnostics and calibration.

Applications exist in the fields of...

  • Upset Monitoring
  • Discharge Monitoring
  • Continuous Monitoring
  • Process Control
  • Carbon Break-thru
  • Oil/Water Separators
  • Treatment Verification
  • Hydrocarbon Leak Detection
  • Pollution Prevention
  • Regulatory Compliance

TD-4100 Specifications

Dimensions: 44.0" x 43.1" x 10.8" (111.8 cm x 109.4 cm x 27.5 cm)
Weight: 64 lbs (29 kg)
Power Requirements: 110 - 240 VAC, 50/60 Hz, 2A
Plumbing Requirements: Feed: 0.5 - 2 gpm (2 - 8L/min), 2" (5.01 cm) unrestricted drain
Air Supply: Dry Air: 10 - 100 psi (68.9 - 689 kPa), 15 SCFH (246 cm3H)
Operating Temperature: 32 - 120o F (0 - 49o C). Contact Turner Designs for configurations in extreme environmental conditions.
Operational Principle: Fluorescence
Detection Range: 1 ppb - > 1000 ppm*
Calibration Stability: 10% or better over 90 days
Response Time: < 10 sec
Sample Temperature: 190o F (95o C) (max)
Calibration: Multi-point calibration
Alarms: Three alarm trigger points (baseline, early warning, and high alarm). Critical components linked to alarms: Local Alarm: Local beep tone; LCD alarm message
Outputs: Signal: 4 - 20 mA, isolated. External Alarm/Device Control: 2 user-settable, independently-fused, solid-state relays (optional AC relay or optional DC relay); relays configurable as Normally Open or Normally Closed; user settable set points and delays
Diagnostics: Self diagnostics: Internal failure mode linked to relays and LCD display
Security: Password protected for Master and User ID; padlockable cabinet
Electronics Cabinet: NEMA 4X
Maintenance: Lamp (twice yearly); routine cleaning of plumbing
Air Purge (optional): Class I Division I; Class I Division II (explosion-proofing)
Data Logger (optional): Digital data storage



 

  TD-4100 On-Line Monitor